HYG-88kVA / 88kV frequency series resonance pressure tester
-
VIDEO CONTENTS
1. This tester should be used by high-pressure test professionals. Before use, you should read the instructions carefully and undergo repeated operation training.
2. The operator should be not less than 2 people. In use, we should strictly observe the safety practice of our unit on high pressure test.
3. In order to ensure the safety and correctness of the test, in addition to being familiar with the product description, we must also conduct test operations strictly in accordance with relevant national standards and procedures.
4. Do not connect the wires incorrectly, otherwise it can cause damage to the test device
5. When using this device, the output is Gaodianya or ultra-high voltage, must be reliably grounded, pay attention to the safety of operation. -
TEST EQUIPMENT LISTS
1 /
Variable frequency power supply control box
HYG-6kVA / 220V/380V
plantform
1 /
6kVA, 30-300Hz
2
Incentive Transformer
JLB-6kVA / 1.5 kV/0 .2 kV/0 .4 kV
plantform
1 /
6kVA, 30-300Hz, 15min
Output voltage: 1.5 kV;
3
High voltage resonator
DK-22kVA / 22kV
plantform
4
22kV, 1A, 96H, 15min.
4
Capacitance divider
FC-90 kV / 1000pF
plantform
1 /
90kV, 1000pF, precision 1.5,
Pure communication -
INSTRUCTIONS
Use appropriate power cord: Only the power cord dedicated to this product and in accordance with this product specification can be used.
Connect and disconnect correctly: When the test wire is connected to a charged terminal, do not connect or disconnect the test wire at will.
Product Grounding: In addition to grounding the product through the power cord grounding wire, the product shell grounding column must be grounded. In order to prevent electric shocks, grounding conductors must be connected to the ground. Make sure this product is properly grounded before connecting to the input or output terminal of this product.
Attention to the ratings of all terminals: In order to prevent fire or electric shock hazards, attention to all ratings and labels of this product. Before connecting this product, please read the product instructions for further information about the rating.
Do not operate without the instrument cover: if the cover or panel has been removed, do not operate this product.
Please do not operate in case of suspicious failure. If you suspect that the product is damaged, please check with our maintenance staff. Please do not continue to operate.
Do not operate in wet conditions.
Do not operate in a volatile environment.
Keep product surface clean and dry