HYG -2880kva/720kv HYG frequency conversion series resonance tester
RELEVANT RECOMMENDATIONS
- HYG-540KVA/54KV Frequency conversion series resonant withstand voltage tester
- HYG-270kVA/270kV Frequency conversion series resonant voltage withstanding test device
- HYG-88kVA / 88kV frequency series resonance pressure tester
- HYG-1350kva/270kv Voltage withstanding tester
- HYG-2400kVA/40kV Frequency Conversion Resonance Test Device
-
VIDEO CONTENTS
Output frequency: 20-300 Hz
Resonant voltage waveform: pure sine wave, waveform distortion rate is less than 1.0%.
Maximum test capacity: 3000 kVA and below
Working system: Full power output works continuously for 15 minutes
Mass coefficient: 30-90
The sensitivity of frequency regulation was 0.1 Hz and the instability was less than 0.05%.
Working power supply: 380/220V+15%/50Hz+5%
-
TEST EQUIPMENT LISTS
Frequency Conversion Control Power Supply, Excitation Transformer, Reactor, Capacitance Voltage Divider
-
INSTRUCTIONS
Use the appropriate power cord: Only the power cord which is special for this product and meets the specifications of this product can be used.
Connect and disconnect correctly: When the test wire is connected to the live terminal, do not connect or disconnect the test wire at will.
Product grounding: In addition to grounding through power line grounding wire, the grounding column of the product shell must be grounded. In order to prevent electric shocks, grounding conductors must be connected to the ground. Before connecting with the input or output terminals of the product, it should be ensured that the product is properly grounded.
Note all terminal ratings: In order to prevent fire or shock hazards, please pay attention to all ratings and markings of this product. Before connecting this product, please read the instructions for the use of this product in order to get more information about the rated value.
Do not operate without instrument cover: If the cover or panel has been removed, do not operate this product.
Do not operate in case of suspected faults: If the product is suspected to be damaged, the company's maintenance personnel should check and do not continue to operate.
Do not operate in humid environment
Do not operate in a violent environment
Keep product surface clean and dry